Ticket #30 (closed Verified Error: Fixed)

Opened 5 years ago

Last modified 5 years ago

simulation needs warm-up

Reported by: jean-philippe Owned by: cp
Priority: Blocker Milestone: 3.1.41
Component: General Seamcat Version: 3.1.40
Keywords: Cc:
Blocked By: Blocking:
Estimated Number of Hours: Pending: no
Add Hours to Ticket: Total Hours:
Original Estimate: Source (can be left blank): Karl Loew
Must be closed before next release: yes Effort Required:

Description

when simulating the gsm-test case, the dRss of the first round of simulation differs from the second round.

the second results is close to the right value -80 dB versus -89dB (previous value reported by karl loew)

Change History

comment:1 Changed 5 years ago by cp

When running the Gsm-Tetra scenario I am unable to reproduce this bug. My working copy is revision [64].

comment:2 Changed 5 years ago by jean-philippe

  • Pending unset
  • billable set to 0

Hi Christian, I am running revision [64] and I can reproduce the same bug. I first get about -64dB and then it converges to about -80dB after the second run. /jp

comment:3 Changed 5 years ago by jean-philippe

  • Priority changed from Major to Critical

comment:4 Changed 5 years ago by jean-philippe

  • Source (can be left blank) set to Karl Loew

comment:5 Changed 5 years ago by jean-philippe

  • Priority changed from Critical to Blocker

comment:6 Changed 5 years ago by cp

  • Must be closed before next release unset

I have tried this on a new PC with the latest source from trunk and is still unable to reproduce. I think we need to verify the source code running in your Eclipse.

comment:7 Changed 5 years ago by cp

  • Must be closed before next release set

comment:8 Changed 5 years ago by jean-philippe

  • Status changed from new to closed
  • Resolution set to Fixed

fixed in [62] by changing coverage radius calculation for the wanted transmitter Ticket closed

Note: See TracTickets for help on using tickets.